“ VISHESH” G-1 |
General Purpose heavy duty alkaline soak cleaner for ferrous and non ferrous metal. It can be used as a electro cleaner and also pre treatment prior to derusting and phosphating. |
Conc:- 40 -60 gm/ltr , temp :- 50 to 60 ⁰ C, time :- 1 to 5 minutes |
“VISHESH” C.E.C.-888 |
Anodic and Cathodic Chelated alkaline Cleaner For brass, Copper & Copper Alloys. Give superb performance for zinc base dicasting in ultrasonic. (no itching for zinc base dicasting) |
For brass and copper Conc:- 60-80 gm/ltr,temperature:-60-80⁰ C, current density:-2-10 A/dm² (cathodic), 2-6 A/dm² (anodic), voltage:-6-8 volt, time :- 1-4 minutes For zinc base dicasting Conc :- 40-60 gm/ltr. In ultrasonic ,temperature:-50-60⁰ C ,time :- 1 – 5 minutes. |
“VISHESH” C.E.C.-999 |
Powerful Anodic and soak alkaline cleaner For Mild steel. It can use by two stage cleaning cycle Soak and electrolytic. |
Conc:- 60-80 gm/ltr, temperature:-70-90⁰ C, Current density:- 60-100 amp/ft², voltage:-6-10 volt,time :- 1-5 minutes. |
“VISHESH” -111 |
Metal cleaner for Rack and Barrel , Can Use from low concentration to high concentration.it remove oils,fats, greases and soil. Very effective for ferrous metal as well as copper and brass. |
Conc:- 10-60 gm/ltr,temperature:- 60-80⁰ C, time:- 1-5 minutes |
“VISHESH” ALM-50 |
Alkaline, Non silicate, Non Causutic. Soak Cleaner for removal of thin film of Oil, Grease and oxides on aluminium, zinc base die casting and other reactive metals. It is ideal for non etch cleaning of all metals prior to anodising and electroplating. It can remove finger print on zinc base die-casting in second stage ultrasonic. |
Conc:-60-80 gm/ltr , temperature:- 55-65⁰ C, time:- 1-5 minutes |
“VISHESH” M-90 |
Cost Effecive Heavy Duty Soak Cleaner For Remove Oil And Soil From Ferrous And Non Ferrous Metal Cleaner. |
Conc:- 60-80 gm/ltr, temperature:- 55-65⁰ C, time:- 1 -5 minutes |
“VISHESH” AB-11 |
Specially design for Bathfitting item in anodic and cathodic cleaning. |
Conc:- 60-70 gm/ltr, Temperature:- 55-60⁰ C, Time :- 1-5 minutes current density:- 2-10 A/dm² (cathodic), 2-6 A/dm² (anodic), voltage:-6-8 volt |